Date / Time

Monday, 20 April 2018 08:88
 

 Main Menu

Home

PACKAGE DEALS

System PayBack Time

Micro Grid -v- State Grid

OFF-GRID Systems

»Frequently Asked Questions ?

»Electricity Retailer Con's !

INVERTERS

  »YIY Hybrid Inverters

  »SOLAR-X Hybrid Inverters

  »Victron Hybrid Inverters

  »Selectronic Hybrid Inverters

BATTERY STORAGE

  »Lithium Iron (LiFePo4) Batteries

  »Nickel Iron (NiFe) Batteries

  »RedFlow - Z-Cell Batteries

  »TESLA Lithium-ion Batteries

  »Super Capacitor (SC) Banks

  »BATTERY Charge/Discharge.

SOLAR POWER

  »Residential Solar

  »Commercial Solar

  »Solar Tracking

  »Single-Axis Tracking (good)

  »Duel-Axis Tracking (better)

Diesel GENERATORS

  »Gen-Set Power Cost Calculator

  »Waste Vegetable Oil as Fuel

WIND Power Generation

AQUA Power Generation

Greenhouse Gas Calculator

Weight & Measurement Converter

»Contact Us

»FREE System Evaluation

»About this business

»Warranty & business policy

 
 
 

System Break-even to Profit period:

One example: We looked at the energy usage of Elizabeth, who has a large freestanding heritage house on there farm near Peak Hill in rural NSW, where she lives with her partner. They both work from home, which makes their energy use higher than most households, But they are sick of constant blackouts, and looking to install DAT Solar and a Battery bank, that will gives them the ability to use ALL there own solar energy, thereafter feeding any excess power into the state grid.

You may want to try one of our pre-set Investment calculators & enter your numbers!

NOTE: It's more important to purchase a battery bank with a kW capacity equal or larger than your daily kW consumption, then you will black-out proof your premises from sunset to sunrise ...for 24hours !

This Micro-Grid calculator shows how Elizabeth can become FREE of the state power grid, it matched there peak power consumption of 28kW day (10'220 kW year) and with another electricity rate increase they now pay @27.47c/kWh =$815.00 per Quarter, including there rural "Service Supply charge" of $108.00 per quarter.

Using the data from there power bills, we recommended two systems consisting of;

  1. 12kW Hybrid Inverter (multi voltage inputs, MPPT & battery management $2'500).
    3.5kW Solar array (10x 350W Panels $2'900).
    26kWh (5x 5.2kWh) LITHIUM Iron battery Rack (48volt, LifePo4 batteries $13'400), this system equipment
    12 panel Duel-Axis Tracking Kit $3'300.
    TOTAL Package Deal $22'100  +installation.
  2. 5kW Hybrid Inverter (multi voltage inputs, MPPT & battery management $1'180).
    3.5kW Solar array (10x 350W Panels $2'900)
    28.8kW NICKEL Iron batteries
    (20x 1.2volt, 1200Ah, 24volt NiFe batteries $17'950).
    12 panel Duel-Axis Tracking Kit $3'300.
    TOTAL Package Deal: $22'420 
    +installation.

Elizabeth is planning a commercial cool room that will substantially increase there power usage, they also have an old un-used Diesel Generator, all that needs to be taken into consideration, as now the retail electricity rate has passes 25 cents kWh, it is actually cheaper to produce electricity using a Diesel generator, saying that not all generators are as economical or as clean a running as each other, and you may want to consider pollution and green house gasses.

Not for everyone: Diesel engines (also known as a compression-ignition or CI engine) were designed to operate on Vegetable Oil, and now will efficiently run long term on very finely filtered Waste Vegetable Oil (WVO), a FREE readily available resource that is bio-degradable.

So, if Elizabeth installed a 3.5kW fixed tilted solar array with all the panels facing North, she can only expect to generate around 15kW of peak power on a average day, as "tilted fixed panel solar arrays" will only harvest 4hrs of Peak energy, with a few kW of energy harvested on the shoulder ramping period each morning & evening.  With Elizabeth outlaying an additional $3'300 to purchase a 12 panel duel-axis solar panel tracking array kit (DAT), there harvesting is greatly increase to exceed there daily kW usage.

Elizabeth's System Payback Break-Even time with a 12 panel DAT array producing 34kWh per 10hr day, saves Elizabeth paying for 28kWh @$0.275 c/kWh for power, save $7.70 per day.  So, if the farm uses 10kWh day during solar hours and 18kWh for the remainder of a 24hr day, leaving 6kW of excess power available to Export into the state power grid, this calculates to 6kWh @$0.08c/kWh a day =$0.48 per day or $175.00 yearly feed-in Tariff, that equates to a total power saving of $3'400 per year, providing approx. 78 month pay back period using Nickel Iron batteries, then the next 20~30+ years Power will be FREE!

Obviously, if they choose to produce more power by installing a larger Solar array and operating their decommissioned Diesel Generator on Waste Vegetable Oil (WVO), it will provide a quicker payback time.  Best-case scenario, WVO is a game changer by producing additional power for virtually free!

Go grab your power bill & use an Investment Break-Even calculator !

OR Click Here to get a FREE system evaluation.

# Based on the unused excess power being harvested @$1.00 Grid-Credit.

 
 
 
:: Events ::
 

 News, Details & Links.

The dirty secrets the Electricity Retailers don't want people to know: Read this article Electricity Retailers Redundant!

See the Cost to self-fund your own Micro Power Grid.

Unlimited Mobile and National calls, Cost just $10 month with AMAYSIM mobile, +get $10 Credit, with No locked in contracts and Free number transfer!

We've been with Amaysim for several years and saved thousand dollars!

 
SA Power Outage in 2016

Privacy Policy | All materials within this website are Copyright © of MicroPowerGrids.com.au 2018